Skip to main content
. 2008 Oct;124(4):2196–2215. doi: 10.1121/1.2968686

Table 1.

Experiment 1 psychometric function (PF) parameters for listeners with normal hearing (LNH) in variable signal (VS), on-frequency forward-masking conditions [QT=quiet threshold; SD=standard deviation].

Signal frequency Masker level Parameter 078 100 102 108 175 Mean(SD)
0.25 kHz QT Threshold 30.84 27.64 38.37 32.36 31.39 32.12 (3.92)
    Slope 1.79 0.99 0.74 0.63 2.04 1.11
    r2 0.99 0.98 0.88 0.92 0.95  
  30 Threshold 31.72 30.55 41.29 34.74 35.07 34.67 (4.17)
    Slope 0.80 1.31 1.34 0.69 1.13 1.02
    r2 0.99 0.99 0.87 0.99 0.96  
  50 Threshold 43.14 45.33 48.51 44.34 45.09 45.28 (2.0)
    Slope 0.72 0.57 1.10 0.37 1.25 0.73
    r2 0.98 0.98 0.97 0.94 1.0  
  70 Threshold 53.20 56.42 59.29 57.74 55.14 56.36 (2.34)
    Slope 0.48 0.47 0.50 0.28 0.73 0.47
    r2 0.96 0.89 0.93 0.82 0.92  
  90 Threshold 64.40 68.00 75.77 72.74 66.24 69.43 (4.71)
    Slope 0.37 0.35 0.38 0.27 0.76 0.40
    r2 0.93 0.96 0.98 0.89 0.98  
4 kHz QT Threshold 17.15 13.28 22.01 16.91 15.27 16.93 (3.24)
    Slope 1.05 1.93 1.16 2.42 1.36 1.58
    r2 0.98 1.00 0.98 0.99 1.00  
  30 Threshold 27.68 23.71 30.10 27.67 27.57 27.35 (2.30)
    Slope 1.24 2.23 0.83 0.52 5.57 1.46
    r2 0.99 0.99 0.85 0.84 1.00  
  50 Threshold 36.16 30.66 43.39 37.32 33.04 36.11 (4.84)
    Slope 1.11 0.73 0.78 0.30 0.91 0.71
    r2 0.99 0.92 0.97 0.86 0.95  
  70 Threshold 40.94 38.86 51.49 50.56 39.08 44.18
    Slope 1.07 0.52 0.53 0.20 0.83 0.55
    r2 0.99 0.96 0.93 0.79 0.95  
  90 Threshold 52.09 50.42 73.14 77.92 53.04 61.32 (13.11)
    Slope 1.00 0.39 0.40 0.28 0.30 0.42
    r2 0.99 0.98 0.90 0.95 0.95