Published in final edited form as: Int J Radiat Oncol Biol Phys. 2008 Aug 1;71(5):1526–1536. doi: 10.1016/j.ijrobp.2008.04.018

Table 3.

A comparison of the dose-volume metrics of 4D plans using the deliverable and 3D optimal methods: the mean and standard deviation (SD) of the dose-volume metric ratios averaged over all 12 patients; and p -values testing whether two distributions are statistically different. Dmean represents the dose received by mean volume of the PTV or OARs, DA% the dose received by A% of volume of the PTV or OARs, and VB the total volume of OARs receiving at least B Gy.

PTV Lungs-GTV Spinal cord
(Dmean)optdel (D95%)optdel (Dmean)optdel (V20)optdel (D0.1%)optdel
Mean ± SD 1.001 ± 0.002 0.995 ± 0.009 1.00 ± 0.02 1.01 ± 0.03 1.00 ± 0.02
min, max 0.999, 1.007 0.974, 1.009 0.97, 1.03 0.97, 1.08 0.96, 1.04
p 0.32 0.39 0.49 0.49 0.50


Esophagus Heart Thorax-PTV
(Dmean)optdel (V55)optdel (Dmean)optdel (V40)optdel (Dmean)optdel

Mean ± SD 1.00 ± 0.02 1.02 ± 0.05 1.01 ± 0.03 1.00 ± 0.10 1.00 ± 0.01
min, max 0.96, 1.03 0.97, 1.11 0.95, 1.05 0.77, 1.20 0.97, 1.02
p 0.50 0.48 0.50 0.49 0.50