TABLE I.
Functional and biomechanical properties of the tendon-to-bone repair.
| Group | Excursion (mm)# | Strain at 20N | Rigidity (N/mm/mm)* | Ultimate Strain# |
|---|---|---|---|---|
| Control | 6.9 ± 0.8 | 0.12 ± 0.04 | 298.4 ± 68.7 | 0.36 ± 0.09 |
| Loaded | 5.2 ± 1.5§ | 0.097 ± 0.05 | 301.5 ± 167.7 | 0.29 ± 0.09 |
| Unloaded | 4.0 ± 1.0§ | 0.15 ± 0.11 | 163.2 ± 71.9§ | 0.42 ± 0.13 |
Loaded vs. Unloaded -
: p<0.10;
: p<0.05
Control vs. Loaded/Unloaded -
: p<0.05