Skip to main content
. 2008 Aug 14;586(Pt 19):4751–4762. doi: 10.1113/jphysiol.2008.157420

Table 1.

Amplitudes and latencies of the electrically evoked action potentials during the control condition (Con), in a hot environment (Hot) and in hot with the head cooled (HHC)

Amplitude (mV) Latency (ms)


Con Hot HHC Con Hot HHC
At rest
3.52 3.25* 3.17* Mmax 14.1 12.9* 13.1*
0.23 0.26 0.27 0.4 0.4 0.4
2.38 1.51* 1.77* Hmax 38.7 36.6* 37.1*
0.32 0.31 0.33 0.7 0.7 0.8
0.72 0.40* 0.54* Hmax/Mmax
0.07 0.09 0.10 (a.u)
Submaximal contraction (10% of MVC)
2.38 1.37* 1.53* Hsup 38.1 35.8* 36.6*
0.29 0.28 0.27 0.7 0.7 0.8
Maximal contraction
3.80 3.40* 3.36* Msup 11.4 10.5* 10.0
0.25 0.29 0.27 0.3 0.3 0.7
1.05 0.78* 0.88 Vsup 36.9 34.4* 35.2*$
0.2 0.19 0.19 0.6 0.6 0.8
0.37 0.21* 0.25* Vsup/Msup
0.08 0.04 0.06 (a.u)
*

Lower than Con

$

higher than Hot, P < 0.05. Data is mean ± S.E.M.