Table 1.

Intra-session reproducibility and the p-values for the comparison of intra-session reproducibility between the three types of DTI data acquisitions for subject 1.

Intra-session reproducibility (mean percentage) Turboprop-DTI SE-EPI-DTI12 SE-EPI-DTI138 P-values
Tp vs. EPI12 Tp vs. EPI138 EPI12vs. EPI138
CST 64.0% 64.8% 69.9% 0.532 0.001 0.142
IFO 49.4% 52.1% 56.9% 0.358 <0.0001 <0.0001
ILF 53.3% 53.7% 67.1% 0.835 <0.0001 <0.0001
UF 55.8% 56.3% 67.1% 0.790 <0.0001 <0.0001
FM 63.2% 69.7% 78.4% <0.0001 <0.0001 <0.0001
Fornix 53.9% 61.0% 64.8% 0.0022 0.0005 0.301

Tp, Turboprop-DTI; EPI12, SE-EPI-DTI12; EPI138, SE-EPI-DTI138.