Skip to main content
. Author manuscript; available in PMC: 2009 Oct 1.
Published in final edited form as: Neuroimage. 2008 Jun 21;42(4):1451–1462. doi: 10.1016/j.neuroimage.2008.05.066

Table 4.

Intra-session reproducibility and the p-values for the comparison of intra-session reproducibility between the three types of DTI data acquisitions for subject 1.

Intra-session reproducibility (mean percentage) Turboprop-DTI SE-EPI-DTI12 SE-EPI-DTI138 P-values
Tp vs. EPI12 Tp vs. EPI138 EPI12 vs. EPI138
CST 57.2% 52.2% 47.8% 0.006 <0.0001 0.001
IFO 44.7% 31.9% 44.8% <0.0001 0.92 <0.0001
ILF 45.9% 26.3% 41.1% <0.0001 0.008 <0.0001
UF 50.9% 32.9% 50.8% <0.0001 0.994 <0.0001
FM 58.7% 46.7% 50.3% <0.0001 0.003 0.02
fornix 48.1% 54.4% 50.3% 0.032 0.423 0.042

Tp, Turboprop-DTI; EPI12, SE-EPI-DTI12; EPI138, SE-EPI-DTI138.