Table III.
Averages of the average γ values and averages of the fraction of points with γ<1 with 2% /2 mm and 3% /3 mm criteria for the 79 dynamic multileaf collimator (DMLC) and 29 segmented multileaf collimator (SMLC) intensity modulated radiation therapy (IMRT) fields. The one-standard deviation for each quantity is given in parenthesis. For each IMRT type, one-way paired ANOVA tests indicated that the improved gamma results for the hybrid method is statistically significant.
| 2% /2 mm |
3% /3 mm |
||||
|---|---|---|---|---|---|
| IMRT type | Method | % pass γ<1 | % pass γ<1 | ||
| DMLC | Hybrid | 0.38 (±0.08) | 92.2 (±3.7) | 0.25 (±0.05) | 99.0 (±0.9) |
| DMLC | PINNACLE3 7.6c | 0.4 (±0.1) | 90.0 (±4.3) | 0.27 (±0.08) | 98.2 (±2.3) |
| DMLC | Analytic 2 | 0.41 (±0.08) | 89.0 (±4.2) | 0.28 (±0.05) | 97.0 (±2.2) |
| DMLC | Analytic 1 | 0.85 (±0.2) | 66.1 (±9.7) | 0.56 (±0.14) | 83.0 (±7.1) |
| SMLC | Hybrid | 0.27 (±0.1) | 94.5 (±6.1) | 0.19 (±0.08) | 98.3 (±2.8) |
| SMLC | PINNACLE3 7.6c | 0.34 (±0.2) | 92.2 (±7.7) | 0.22 (±0.12) | 97.1 (±4.3) |
| SMLC | PINNACLE3 6.2b | 0.41 (±0.22) | 89.2 (±9.5) | 0.27 (±0.14) | 96.0 (±4.9) |