Skip to main content
. 2008 Dec 11;8:45. doi: 10.1186/1471-2377-8-45

Table 3.

Cut off points and prediction probabilities in the stroke.

Variable Cut off CE stroke NCE stroke Overall Accuracy
Plasma BNP 77 pg/ml 47/62 (75.8%) 53/69 (76.8%) 100/131 (76.3%)
E/A 0.92 16/19 (84.2%) 56/69 (81.2%) 72/88 (81.8%)
LA diameter 36 mm 49/62 (79.0%) 57/69 (82.6%) 106/131 (80.9%)
LAA flow 67 cm/s 52/62 (83.9%) 58/69 (84.1%) 110/131 (84.0%)

CE: cardioembolic; NCE non-cardioembolic.