Skip to main content
. 2003 Nov;69(11):6946–6948. doi: 10.1128/AEM.69.11.6946-6948.2003

TABLE 1.

Chemical and biological characteristics of inlet water and Propella reactors A and B before and after introduction of M. xenopia

Water or biofilmb pH TOC (mg/liter) Free chlorine (mg/liter) Total chlorine (mg/liter) Culturable bacteria after 72 h (CFU)c Total cell countc
Inlet water 7.5 ± 0.19 1.2 ± 0.2 0.03 ± 0.01 0.04 ± 0.01 56 ± 27 (1.76 ± 0.16) × 105
Outlet water (Propella reactors A and B)
    Before M. xenopi (n = 5) 7.6 ± 0.1 1.2 ± 0.2 0d 0 (4.5 ± 4.7) × 103 (3.2 ± 1.4) × 105
    After M. xenopi (n = 9) 7.6 ± 0.2 1.3 ± 0.2 0 0 (4.5 ± 8.5) × 103 (3.6 ± 1.3) × 105
Biofilm (Propella reactors A and B)
    Before M. xenopi (n = 2) (1.1 ± 0.5) × 105 (62 ± 2.9) × 105
    After M. xenopi (n = 9) (1.3 ± 2) × 105 (84 ± 31) × 105
a

All values are averages ± standard deviations.

b

n, number of analyses used for the calculation of averages.

c

Values are per milliliter for water and per square centimeter for biofilm.

d

A value of zero indicates a measurement below the detection limit of 0.02 mg/liter.