Skip to main content
. 2008 Nov 9;8:42. doi: 10.1186/1471-2377-8-42

Table 3.

Contingency of the 32 patients who underwent both SN-TCD and postsynaptic SPECT imaging

Total number of patient n = 32 postsynaptic SPECT abnormal postsynaptic SPECT normal
SN-TCD positive (= abnormal) 6a 15c
SN-TCD negative (= normal) 3b 8d

SN substantia nigra, TCD transcranial duplex, SPECT Single Photon Emission Computer Tomography

a: IPD 2, APS 2, inconclusive 2

b: IPD 2, APS 1

c: IPD 13, APS 1, inconclusive 1

d: IPD 4, VP 3, 1 restgroup