Reversal Potential (Erev) and Permeability Ratios (PX/PCl−) for CASTOR and castor-2

CASTOR
castor-2
Ion (X) Erev (mV) PX/PCl− Erev (mV) PX/PCl−
K+ 36 ± 2 (n = 40) 6.0a 28 ± 2 (n = 48) 3.7a
Na+ 11 ± 1 (n = 8) 1.6a 25 ± 3 (n = 13) 3.2a
Ca2+ −29 ± 2 (n = 13) 0.5b −32 ± 2 (n = 19) 0.6b
a

Permeability ratios calculated from reversal potentials using equation Erev = RT/zF × ln(PK+[K]o/PNa+[Na]i).

b

Permeability ratios calculated from reversal potentials using equation Erev= RT/F × ln(√((4PCa2+[Ca]o/PK+[K]i)+1/4) − 1/2), where RT/F = 25.26 mV and Z = 1. The junction potential correction was as follows: NaCl (250 mM/20 mM, agar bridge, 2 M KCl), Vm = Vcmd + 2.3 mV; KCl (250 mM/20 mM, agar bridge, 2 M KCl), Vm = Vcmd + 1.2 mV; CaCl2 (125 mM/10 mM, agar bridge, 2 M KCl), Vm = Vcmd + 3.1 mV.