Table 2. Correlation of different crystallographic parameters with the minimal accuracy of a de novo model required to phase the 30 diffraction data sets in Table 1 ▶ .
| Crystallographic parameter | r2 | P value† |
|---|---|---|
| No. of modeled residues | −0.592 | 5.7 × 10−4 |
| Highest resolution reflection | 0.232 | 0.22 |
| Lowest resolution reflection | −0.229 | 0.22 |
| No. of copies in asymmetric unit | 0.200 | 0.29 |
| No. of reflections | −0.146 | 0.44 |
| Matthews coefficient (VM) | −0.095 | 0.62 |
| No. of reflections > 4 Å | −0.091 | 0.64 |
| No. of reflections > 6 Å | −0.079 | 0.68 |
| No. of residues in asymmetric unit | −0.038 | 0.84 |
| Solvent content | −0.022 | 0.91 |
Correlations are to F 1 Å, the fraction of Cα atoms within 1 Å of the crystal structure, of the least accurate model that gives an unambiguous Phaser hit (see Table 1 ▶).