Skip to main content
. 2009 Jan 20;65(Pt 2):169–175. doi: 10.1107/S0907444908020039

Table 2. Correlation of different crystallographic parameters with the minimal accuracy of a de novo model required to phase the 30 diffraction data sets in Table 1 .

Crystallographic parameter r2 P value
No. of modeled residues −0.592 5.7 × 10−4
Highest resolution reflection 0.232 0.22
Lowest resolution reflection −0.229 0.22
No. of copies in asymmetric unit 0.200 0.29
No. of reflections −0.146 0.44
Matthews coefficient (VM) −0.095 0.62
No. of reflections > 4 Å −0.091 0.64
No. of reflections > 6 Å −0.079 0.68
No. of residues in asymmetric unit −0.038 0.84
Solvent content −0.022 0.91

Correlations are to F 1 Å, the fraction of Cα atoms within 1 Å of the crystal structure, of the least accurate model that gives an unambiguous Phaser hit (see Table 1).