Skip to main content
. Author manuscript; available in PMC: 2009 Sep 1.
Published in final edited form as: J Chromatogr B Analyt Technol Biomed Life Sci. 2008 Jul 31;872(1-2):141–147. doi: 10.1016/j.jchromb.2008.07.032

Table 4.

Stability of ABT-888 and M8 under varying conditions.

Storage condition Concentration (ng/mL) Stability (%) CV (%) Replicates

ABT-888

Stock solution 4 h
  Ambient temp.
1,000,000 101.8 4.0 3
Stock solution 3 months
  4 °C
1,000,000 104.9 2.9 3
Plasma 4 h
  Ambient temp.
QCL 20 106.5 6.7 3
QCM 200 95.7 7.0 3
QCH 800 101.9 7.5 3
Plasma 3 freeze-thaw cycles
  −80 °C
QCL 20 102.1 2.5 3
QCM 200 98.9 4.9 3
QCH 800 100.0 4.4 3
Plasma 3 months
  −80 °C
QCL 20 113.9 4.3 3
QCM 200 98.2 6.2 3
QCH 800 98.5 4.2 3

M8

Stock solution 4 h
  Ambient temp.
1,000,000 101.0 3.5 3
Stock solution 3 months
  4 °C
1,000,000 98.2 5.8 3
Plasma 4 h
  Ambient temp.
QCL 20 105.0 12.5 3
QCM 200 94.4 8.1 3
QCH 800 99.9 6.6 3
Plasma 3 freeze-thaw cycles
  −80 °C
QCL 20 102.8 13.9 3
QCM 200 94.4 5.1 3
QCH 800 96.8 4.3 3
Plasma 3 months
  −80 °C
QCL 20 90.5 15.6 3
QCM 200 92.7 12.2 3
QCH 800 89.2 9.8 3