Skip to main content
. 2008 Nov 13;9(11):2231–2242. doi: 10.3390/ijms9112231

Table 2.

Correlationsa of the specific rates of solvolyses of 1, and a comparison with the corresponding specific rate values for 2 and 3 in identical solvents.

Substrate nb c mc cc l/m Rd Fe
29f 1.85±0.21 0.48±0.05 0.14±0.05 3.85 0.871 41
1 39g 1.68±0.06 0.46±0.04 0.074±0.08 3.65 0.976 363
38h 1.69±0.07 0.46±0.04 0.074±0.08 3.67 0.974 323
2 38h 1.59±0.07 0.54±0.03 0.16±0.08 2.94 0.972 299
3 38h 1.58±0.06 0.57±0.04 0.17±0.07 2.77 0.974 320

a Using equation (2).

b Number of data points.

c With associated standard error.

d Correlation coefficient. e F-test value.

f Specific rates are from the 29 solvents reported in refs. [32, 33].

g Specific rates are those from Table 1 plus the 29 used in refs. [32, 33].

h Without 90T-10E; using identical solvents for the 38 data-point correlation of the specific rates of solvolysis of 1, 2, and 3.