Table 1.
The mean percentages of minimum, maximum and mean planning target volume (PTV) doses ± standard deviation for all plans
Mean dose (range) % ± SD | |||
Single field-ICRUrp | Single field-IBMCrp | Two opposed fields | |
Minimums | 77.3 (72–81) ± 2.6 | 83.7 (74–89) ± 3.3 | 91 (90–95) ± 1.3 |
Maximums | 122.2 (114–130) ± 4.3 | 133.9 (115–147) ± 7.1 | 108.8 (104–110) ± 1.3 |
Means | 99.8 (94–107) ± 2.6 | 108.8 (95–116) ± 3.3 | 99.7(97–102) ± 1.3 |
ICRUrp, the International Commission on Radiation Units and Measurements reference point; IBMCrp, the International Bone Metastasis Consensus Working Party reference point; SD, standard deviation.