Audiometric data for hearing-impaired listeners (HI1–HI7). The ear tested is associated with the entries in bold. The %Sp column refers to speech recognition for monosyllabic words in quiet with presentation level approximately 30 dB above the speech recognition threshold for spondee words. “NR” indicates that the threshold was above the limits of audiometric testing and “DNT” indicates that the test was not performed.

Left
Right
.25 .5 1.0 2.0 4.0 8.0 %Sp .25 .5 1.0 2.0 4.0 8.0 %Sp
HI1 40 45 45 35 45 85 84 NR NR NR NR NR NR DNT
HI2 50 55 60 60 60 65 92 40 35 45 45 45 45 88
HI3 25 30 50 50 50 35 92 25 30 40 50 50 40 92
HI4 20 20 20 20 20 15 100 50 55 55 40 40 40 92
HI5 35 35 25 30 40 60 100 25 30 30 30 45 65 100
HI6 25 40 45 30 55 85 88 15 15 10 5 5 10 100
HI7 25 50 60 45 35 50 88 10 40 45 45 45 35 96