Skip to main content
. Author manuscript; available in PMC: 2009 Feb 26.
Published in final edited form as: J Control Release. 2005 Jun 2;104(3):433–446. doi: 10.1016/j.jconrel.2005.02.022

Fig. 3.

Fig. 3

Multiple lumen conduits. Conduits were fabricated with HMW PLG containing 18 channels (diameter=250 µm) and visualized by light microscopy. Conduit is visualized from the top (A, scale bar=1 mm) and from the end (B, scale bar=500 µm).