Table 1. Data-collection statistics for the oligonucleotide crystal.

Values in parentheses are for the highest resolution shell.

Data set Neutron X-ray
Beamline LADI-III Rotating anode
Wavelength (Å) 3.1–4.2 1.54
No. of images 18 89
Oscillation angle (°) 5 1
Exposure time per image (min) 720 1
Space group P6122
Unit-cell parameters (Å) a = b = 33.021, c = 78.817
Resolution range (Å) 26.88–2.30 (2.42–2.30) 26.88–1.92 (2.02–1.92)
No. of unique reflections 1082 (119) 2218 (265)
Completeness (%) 82.4 (66.6) 97.7 (84.5)
Rmerge 0.18 (0.25) 0.043 (0.383)
Multiplicity 6.2 (2.8) 8.7 (7.3)
Mean I/σ(I) 11.8 (2.1) 19.3 (4.1)
Wilson B factor (Å2) 32.1 36.0