Table 3.
Date | Specific gravity | Blood | Protein | Comments |
8/25/2005 | 1.012 | 3+ | 3+ | Collected from pan with plastic liner; sample clear yellow in color; refractometer used; cytology not performed |
9/23/2005 | 1.012 | 3+ | 2+ | Collected from pan with plastic liner; sample clear yellow in color; refractometer used; cytology not performed |
11/18/2005 | 1.010 | 3+ | 3+ | Collected from pan with plastic liner; sample clear yellow in color; refractometer used; cytology revealed myriad bacteria with plant debris and some desquamated epithelial cells, but red blood cells were not a prominent finding |
12/7/2005 | 1.005 | none | 3+ | Collected by cystocentesis; sample clear yellow in color; refractometer used; cytology revealed predominately epithelial cells with few neutrophils and lymphocytes; culture negative after 10 d |
12/15/2005 | 1.010 | none | 2+ | Collected by cystocentesis at necropsy; sample clear yellow in color; reagent strip used; cytology not performed; culture negative after 10 d |