Skip to main content
. 2001 Mar 10;322(7286):577. doi: 10.1136/bmj.322.7286.577

Table 3.

Numbers (percentages) of patients managing to perform different aspects of priming and loading the Relenza Diskhaler at initial review and at 24 hours

Aspect of technique Time of review
Initial (n=38) At 24 hours (n=37)
Removing top 37 (97)  37 (100)
Rotating disc for intact blister 26 (68) 14 (38)
Perforating blister 26 (68) 19 (51)
Replacing perforator 23 (61) 19 (51)
Removing tray 16 (42) 9 (24)
Changing disc 17 (45) 14 (38)
Replacing tray 16 (42) 14 (38)