Skip to main content
. Author manuscript; available in PMC: 2010 Mar 10.
Published in final edited form as: Circulation. 2009 Feb 23;119(9):1253–1262. doi: 10.1161/CIRCULATIONAHA.108.798983

Table 2.

In vivo hemodynamics

NTG β-TG cMyBP-CWT:(t/t)/β cMyBP-CAllP+:(t/t)/β

Basal Dobut. Basal Dobut. Basal Dobut. Basal Dobut.
Heart rate (bpm) 382±10 597±17 295±21* 399±35* 322±11* 425±15* 346±16 561±20#
LVP (mm Hg/s) 108±5 121±7 77±4* 86±2* 79±5* 94±3* 103±4# 113±4#
dP/dtmax (mm Hg/s) 10253±561 24575±627 5631±363* 13789±689* 6555±396* 14322±529* 12680±455*# 18395±479*#
dP/dtmin (mm Hg/s) -9767±-617 -18687±-867 -5410±-339* -8630±-806* -5916±-1006* -9164±-404* -8860±-951# -12291±-1084*#

Cardiac catheterization was used to evaluate LV function.1 Heart rate, peak LV pressure (LVP) maximum, LV dP/dtmax (an index of myocardial contractility) and LV dP/dtmin (an index of myocardial relaxation), were determined at baseline (basal) and during infusion of dobutamine (Dobut; 32 ng/g/min). All data are presented as mean±SE.

*

P<0.001 versus NTG

#

P<0.05 versus cMyBP-CWT:(t/t)/β (n=6).