Table 1.
Determinant |
No. of measurements | Mean (mg m−3) | Industry typea | Fluid typeb | P-value | Reference | |
Total aerosol fraction including inhalable | |||||||
Decade | 1958–1969 | 40 | 5.42 | 1 | 1, 2 and 3 | <0.05 | Hallock et al. (1994) |
1970–1974 | 74 | 2.67 | |||||
1975–1979 | 148 | 2.24 | |||||
1980–1987 | 132 | 1.82 | |||||
1970s | 21 plants | 1.23 | 4-1 | NI | NI | NIOSH (1998) | |
1980s | 15 plants | 0.57 | |||||
1990s | 2 plants | 1.00 | |||||
1979–95 | NI | 0.92 | 4-2 | NI | NI | NIOSH (1998) | |
1989–94 | NI | 0.49 | |||||
Industry type | Electrical components (SIC 3643) | 15 | GM = 1.15 | 3 | A | NI | Piacitelli et al. (2001) |
Speed changers (SIC 3566) | 55 | GM = 0.71 | |||||
Bolts, nuts, screws, rivets and washers (SIC 3452) | 34 | GM = 0.66 | |||||
Metal-cutting machine tools (SIC 3451) | 55 | GM = 0.51 | |||||
Other 19 industries | 872 | GM range = 0.14–0.49 | |||||
Location | USA northeast | NI | 0.56 | 3 | A | <0.05 | Piacitelli et al. (2001) |
versus USA west | NI | 0.39 | |||||
and versus USA midwest | NI | 0.39 | |||||
Age of machine | Old machines (≥30 years) | NI | GM = 0.48 | 3 | A | <0.05 | Piacitelli et al. (2001) |
versus new machines (<10 years) | NI | GM = 0.34 | |||||
Operation type | Grinding and | 119 | GM = 0.67 | 3 | A | <0.05 | Piacitelli et al. (2001) |
Hobbing | 37 | GM = 0.60 | |||||
versus other machining operationsc | 741 | GM range = 0.27–0.51 | |||||
Grinding | 9 | 0.72 | 1 | 1 and 2 | NI | Woskie et al. (1996) | |
Multiple drills | 25 | 0.36 | |||||
Other machining operationsd | 182 | 0.19–0.24 | |||||
Multiple drills | 25 | GM = 0.25 | 1 | 1 and 2 | <0.05 | Woskie et al. (1996) | |
Grinding | 9 | GM = 0.17 | |||||
Drills | 64 | GM = 0.16 | |||||
Lathes | 61 | GM = 0.16 | |||||
Other machining operationsd | 118 | GM range = 0.19–0.21 | |||||
Grinding in 1958–1969 | 7 | 17.96 | 1 | A | NI | Hallock et al. (1994) | |
Machininge in 1958–1969 | 25 | 3.67 | |||||
Grinding in 1970–1979 | 71 | 3.44 | |||||
Machininge in 1970–1979 | 128 | 2.13 | |||||
Grinding in 1980–1987 | 56 | 2.28 | |||||
Machininge in 1980–1987 | 61 | 1.66 | |||||
Grinding | 61 | 0.73 | 2 | 2 | NI | Simpson et al. (2003) | |
Multiple operations | 42 | 0.71 | |||||
Other machining operationsd | 188 | 0.13–0.27 | |||||
Grinding | 23 | 0.49–0.96 | 1 | 3 and 4 | NI | Kenyon et al. (1993) | |
Other machining operationsf | 66 | 0.26–5.99 | 2, 3 and 4 | ||||
Face grinding | 15 | 0.49 | 1 | NI | Rosenthal and Yeagy (2001)g | ||
Progressive grinding | 15 | 0.77 | |||||
Microcentric grinding | 14 | 0.55 | |||||
Machining on and fluid delivery on | 13 | 0.94g | 1 | 2 | 0.006 | Sheehan and Hands (2007) | |
Machining off and fluid delivery on | 13 | 0.91g | 0.006 | ||||
versus machining off and fluid delivery off | 13 | 0.19g | |||||
MWF type | Straight and | 359 | GM = 0.52 | 3 | NA | <0.05 | Piacitelli et al. (2001) |
Synthetic | 106 | GM = 0.45 | |||||
versus soluble | 242 | GM = 0.34 | |||||
and versus semisynthetic | 158 | GM = 0.33 | |||||
Straight | 74 | 0.24 | 2 | NI | Woskie et al. (1996) | ||
Soluble | 139 | 0.22 | |||||
Straight | 45 | 1.11 | 2 | NA | NI | Simpson et al. (2003) | |
Water miscible | 296 | 0.67 | |||||
Level of engineering control | OEM enclosures with LEV | 92 | Median = 0.21 | 1 | NI | <0.05 | Hands et al. (1996) |
versus retrofit enclosures with LEV | 213 | Median = 0.45 | |||||
and versus little no enclosure | 150 | Median = 0.48 | |||||
Before upgraded enclosure | 11 | GM = 2.24g | 1 | 2 | <0.0001 | Sheehan and Hands (2007) | |
After upgraded enclosure | 11 | GM = 0.19g | |||||
New transfer line | 18 | 0.26 | 1 | 2 | 0.003 | Sheehan and Hands (2007) | |
Old transfer line | 18 | 0.49 | |||||
Old technology (machining)e | NI | 0.40 | 1 | 2 | NI | Dasch et al. (2005) | |
New technology (machining)e | NI | 0.07 | 4 | ||||
Old technology (grinding) | NI | 1.10 | 2 | ||||
New technology (grinding) | NI | 0.08 | 1 | ||||
No enclosure or splash | NI | GM = 0.36 | 3 | A | NS | Piacitelli et al. (2001) | |
versus with splash guard | NI | GM = 0.45 | |||||
OEM splash guards | NI | GM = 0.50 | NS | ||||
versus retrofit splash guards | NI | GM = 0.38 | |||||
Thoracic fraction | |||||||
Operation type | Grinding | 33 | GM = 0.36 | 3 | A | NI | Piacitelli et al. (2001) |
Hobbing | 12 | GM = 0.42 | |||||
Other machining operationsc | 278 | GM range = 0.13–0.24 | |||||
Case department | 215 | 0.56 | 1 | 2 | <0.05 | Abrams et al. (2000) | |
Valve body department | 145 | 0.32 | 2 | ||||
Fluid type | Straight | 81 | GM = 0.27 | 3 | NA | NI | Piacitelli et al. (2001) |
Soluble | 73 | GM = 0.18 | |||||
Synthetic | 31 | GM = 0.28 | |||||
Semisynthetic | 41 | GM = 0.23 | |||||
Respirable fraction | |||||||
Fluid type | Mostly straight | 6 | 0.72g | 1 | NA | NI | Chan and D'Arcy (1990)g |
Soluble | 10 | 0.41g | |||||
Synthetic and semisynthetic | 6 | 0.32g | |||||
Semisynthetic | 8 | 0.37g | |||||
Synthetic | 8 | 0.22g | |||||
Straight | 9 | 0.25g | |||||
Enclosure and operation | Cam–crank with retrofitted enclosure in spring | 150 | GM = 0.18g | 1 | NI | NI | Peters et al. (2006)g |
Cam–crank with retrofitted enclosure in winter | 35 | GM = 0.20g | |||||
Block-head-rod with new enclosure in spring | 178 | GM = 0.04g | |||||
Block-head-rod with new enclosure in winter | 38 | GM = 0.06g |
IMIS = Integrated Management Information System, NI = not indicated and NS = not statistically significant.
Industry type: 1 = auto or auto part manufacturing, 2 = UK engineering industry, 3 = small-job machine shop, 4-1 = NIOSH Health Hazard Evaluation US national survey and 4-2 = Occupational Safety and Health Administration IMIS US national survey that NIOSH analyzed.
Fluid type: 1 = straight, 2 = soluble, 3 = synthetic, 4 = semisynthetic and A = all types or not specified.
Turning, sawing, milling, drilling, stamping and mixed operations.
Broaches, chuckers and mixed operations.
Type of machining was not identified.
Turning, milling, drilling and sawing.
Area sample taken near working area