Skip to main content
. 2009 Mar 17;4:11. doi: 10.1186/1748-717X-4-11

Table 2.

Radiation treatment parameters

Median Minimum Maximum
Dose @ isocenter (Gy)*
 All patients 14 6* 20
 Upfront SRS 13 6* 20
 SRS at recurrence 15 9 20
Peripheral dose (%)
 All patients 80 40 100
 Upfront SRS 80 50 100
 SRS at recurrence 80 40 90
Number of isocenters
 All patients 2 1 7
 Upfront SRS 1 1 3
 SRS at recurrence 2 1 7
Number of beams/arcs
 All patients 12 6 32
 Upfront SRS 12 7 24
 SRS at recurrence 12 6 32
GTV (ml)
 All patients 9.2 0.2 85.4
 Upfront SRS 13.2 1.5 85.4
 SRS at recurrence 8.4 0.2 32.2
Upfront fractionated RT dose (all patients) 60 50 65

* because of worsening neurological symptoms, large treatment volume and critical location, one patient was prescribed an unusually low isocenter dose of 6 Gy.