Skip to main content
. 2009 Apr;4(4):719–725. doi: 10.2215/CJN.03750708

Table 3.

(Post-pre) kidney volume differences and percent differences in the right, left and total kidney measurements made by two readers. The postgadolinium volumes were significantly higher than the pregadolinium volumes

Kidney Reader Volume difference (post − pre) (mL)
Volume %difference [(post − pre)/pre]x100
Mean SD P value P value (reader effect) Mean SD P value P value (reader effect)
Right R1 16.49 14.84 0.001 0.006 4.98 6.26 0.002 0.010
R2 24.41 14.69 0.000 6.87 6.51 0.001
Left R1 11.99 22.59 0.028 0.029 4.34 5.51 0.002 0.020
R2 24.87 21.11 0.000 6.56 7.11 0.001
Total R1 28.48 31.00 0.001 0.003 4.57 5.24 0.001 0.005
R2 49.28 26.27 0.000 6.59 6.25 0.000