Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1988 Sep;26(9):1775–1778. doi: 10.1128/jcm.26.9.1775-1778.1988

Retrospective evaluation of the Du Pont radioimmunoassay kit for detection of Legionella pneumophila serogroup 1 antigenuria in humans.

M E Aguero-Rosenfeld 1, P H Edelstein 1
PMCID: PMC266714  PMID: 3183024

Abstract

We used the Du Pont radioimmunoassay kit for soluble Legionella pneumophila serogroup 1 antigenuria (Du Pont Co., Wilmington, Del.) to test 422 urine samples from patients with and without Legionnaires disease (LD). The urine specimens were collected from 23 patients with culture-proven LD and from 346 patients without LD. L. pneumophila serogroup 1 was isolated from 14 patients with culture-proven LD, and other L. pneumophila serogroups or other Legionella species were isolated from 9 patients; 58 urine specimens were tested from these 23 patients. The non-LD group was composed of 75 bacteremic patients (35 gram-negative and 40 gram-positive bacteremias), 7 patients with candidemia, 48 patients with non-LD pneumonia, 90 patients with gram-negative bacteriuria (greater than 10(5) CFU/ml), 23 patients with gram-positive bacteriuria (greater than 10(5) CFU/ml), 14 patients with candiduria (greater than 10(5) CFU/ml), and 89 outpatients with negative urine cultures. All tests were performed in duplicate, including positive and negative controls. Sample results with values greater than or equal to 3.0 times those of the negative controls were considered positive for L. pneumophila serogroup 1 antigenuria. The average sample-to-negative ratios were 19.1 for the L. pneumophila serogroup 1 specimens, and 1.0 for both the non-serogroup 1 legionella group and the non-LD specimens. All but one of the patients who were culture positive for L. pneumophila serogroup 1 had at least one specimen positive for serogroup 1 antigenuria; none of the non-L. pneumophila serogroup 1 patients had a positive urine test. The test was highly specific (100%) and sensitive (93%) for the detection of L. pneumophila serogroup 1 antigenuria. Concentrations of urine by vacuum evaporation increased test sensitivity without apparently affecting specificity.

Full text

PDF
1778

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Berdal B. P., Farshy C. E., Feeley J. C. Detection of Legionella pneumonophila antigen in urine by enzyme-linked immunospecific assay. J Clin Microbiol. 1979 May;9(5):575–578. doi: 10.1128/jcm.9.5.575-578.1979. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Kohler R. B., Wheat L. J., French M. L., Meenhorst P. L., Winn W. C., Jr, Edelstein P. H. Cross-reactive urinary antigens among patients infected with Legionella pneumophila serogroups 1 and 4 and the Leiden 1 strain. J Infect Dis. 1985 Nov;152(5):1007–1012. doi: 10.1093/infdis/152.5.1007. [DOI] [PubMed] [Google Scholar]
  3. Kohler R. B., Winn W. C., Jr, Wheat L. J. Onset and duration of urinary antigen excretion in Legionnaires disease. J Clin Microbiol. 1984 Oct;20(4):605–607. doi: 10.1128/jcm.20.4.605-607.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Kohler R. B., Zimmerman S. E., Wilson E., Allen S. D., Edelstein P. H., Wheat L. J., White A. Rapid radioimmunoassay diagnosis of Legionnaires' disease: detection and partial characterization of urinary antigen. Ann Intern Med. 1981 May;94(5):601–605. doi: 10.7326/0003-4819-94-5-601. [DOI] [PubMed] [Google Scholar]
  5. Kohler R., Wheat L. J. Rapid diagnosis of pneumonia due to Legionella pneumophila serogroup 1. J Infect Dis. 1982 Sep;146(3):444–444. doi: 10.1093/infdis/146.3.444. [DOI] [PubMed] [Google Scholar]
  6. Mangiafico J. A., Hedlund K. W., Knott A. R. Rapid and sensitive method for quantitation of Legionella pneumophila serogroup 1 antigen from human urine. J Clin Microbiol. 1981 May;13(5):843–845. doi: 10.1128/jcm.13.5.843-845.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Sathapatayavongs B., Kohler R. B., Wheat L. J., White A., Winn W. C., Jr, Girod J. C., Edelstein P. H. Rapid diagnosis of Legionnaires' disease by urinary antigen detection. Comparison of ELISA and radioimmunoassay. Am J Med. 1982 Apr;72(4):576–582. doi: 10.1016/0002-9343(82)90451-x. [DOI] [PubMed] [Google Scholar]
  8. Sathapatayavongs B., Kohler R. B., Wheat L. J., White A., Winn W. C., Jr Rapid diagnosis of Legionnaires' disease by latex agglutination. Am Rev Respir Dis. 1983 May;127(5):559–562. doi: 10.1164/arrd.1983.127.5.559. [DOI] [PubMed] [Google Scholar]
  9. Tang P. W., Toma S. Broad-spectrum enzyme-linked immunosorbent assay for detection of Legionella soluble antigens. J Clin Microbiol. 1986 Oct;24(4):556–558. doi: 10.1128/jcm.24.4.556-558.1986. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Tang P. W., de Savigny D., Toma S. Detection of Legionella antigenuria by reverse passive agglutination. J Clin Microbiol. 1982 Jun;15(6):998–1000. doi: 10.1128/jcm.15.6.998-1000.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Tilton R. C. Legionnaires' disease antigen detected by enzyme-linked immunosorbent assay. Ann Intern Med. 1979 Apr;90(4):697–698. doi: 10.7326/0003-4819-90-4-697. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES