Table 5.

Measured percent change in the slope-to-intercept ratio of the MTP versus dose line for a variety of MT powers and offset frequencies for the MAGIC dosimeter. For most powers and offset frequencies, the slope-to-intercept ratio does not vary more than 10% for even a 10% error in B1 pulse angle.

Error in B1 pulse angle
Offset frequency −10% −5% No error +5% +10%
MT power = 4.44 μT
1375 −0.61% −1.73% 0.0941 −1.39% 10.05%
1787 −12.68% −11.43% 0.0941 −0.92% 5.96%
2322 −3.80% 0.87% 0.0815 6.87% 18.92%
3018 −11.07% −6.75% 0.0766 12.06% 13.41%
MT power = 8.88 μT
1375 −6.17% 0.42% 0.1151 5.51% 3.11%
1787 6.16% 5.15% 0.1058 10.53% 14.42%
2322 −5.31% 4.14% 0.1087 0.45% 12.76%
3018 −3.03% −4.00% 0.1051 8.16% 8.78%