Skip to main content
. 2008 Dec 15;587(Pt 3):551–565. doi: 10.1113/jphysiol.2008.161737

Table 2.

Rate parameters for the HERG model (Scheme 1)

Forward rates
Backwards rates
A z A z
k1 2 0.6 k−1 50 −0.6
k2 10 k−2 10
k3 14 1.5 k−3 0.1 −1.5
k4 90 0.6 k−4 20 −0.6

A (s−1) is the rate constant at 0 mV and z is the charge moved.