TABLE 5.
Condition | K1 | A1 | K2 | A2 |
---|---|---|---|---|
min–1 | % | min–1 | % | |
d-Amph (100 nM) | 0.027 ± 0.01 | 22 ± 6 | 0.19 ± 0.02 | 88 ± 5 |
d-Amph (100 nM) + SoRI-9804 (0.4 μM)† | 0.028 ± 0.013 | 33 ± 18 | 0.14 ± 0.04 | 74 ± 16 |
d-Amph (100 nM) + SoRI-9804 (2.0 μM)† | 0.035 ± 0.01 | 59 ± 12* | 0.21 ± 0.07 | 50 ± 10* |
d-Amph (100 nM) + SoRI-9804 (10 μM)† | 0.021 ± 0.004 | 58 ± 11* | 0.15 ± 0.05 | 45 ± 10* |
d-Amph (100 nM) + SoRI-9804 (25 μM)† | 0.023 ± 0.004 | 65 ± 10* | 0.19 ± 0.06 | 43 ± 9* |
The A values of the curve (constraint 4; see Materials and Methods) were significantly different (F-test, P < 0.01) from the 100 nM d-Amph curve. The kinetic constants of each curve did not significantly differ from those of the 100 nM d-Amph curve
The entire curve (constraint 1; see Materials and Methods) was significantly different (F-test, P < 0.01) from the 100 nM d-Amph curve