Table 5.

Number of landmark pairs (LPs) used to compute target modeling errors (TME), modeling error (ME), modeling prediction error (MPE), and boundary discontinuity (BD). Values enclosed in braces are the maximum error values.

Patient Inverse 5D model Forward 5D model
LP TME (mm) ME (mm) MPE (mm) BD (mm) LP TME (mm) ME (mm) MPE (mm) BD (mm)
1 131 1.02±0.52 (2.6) 0.40±0.31 0.40±0.37 1.0±0.8 (6.1) 2025 0.52±0.32 (2.8) 0.19±0.36 0.24±0.39 0.9±0.8 (6.7)
2 37 1.71±1.04 (4.4) 0.38±0.29 0.27±0.35 0.7±0.6 (4.5) 929 0.59±0.36 (3.0) 0.25±0.42 0.27±0.48 0.7±0.5 (5.1)
3 42 1.04±0.49 (2.3) 0.77±0.63 0.55±0.82 1.5±0.9 (6.1) 1198 0.67±0.61 (4.9) 0.37±0.62 0.47±0.77 1.4±1.1 (5.2)