Skip to main content
. 2009 Jan 28;116(4):552–561. doi: 10.1111/j.1471-0528.2008.02063.x

Table 1.

Baseline values and observed changes related to fluids given until birth. Group differences analysed using Kruskal–Wallis nonparametric ANOVA and Mann–Whitney U test

Control group elective caesarean (n = 26) Total fluids given until birth Kruskal–Wallis P value Mann–Whitney P value

Fluid group 1 <1000 ml (n = 113) Fluid group 2 1000–2500 ml (n = 87) Fluid group 3 >2500 ml (n = 61)




Median Q1–Q3 Median Q1–Q3 Median Q1–Q3 Median Q1–Q3
Mother
Age 32 27–35 31 28–34 30 27–33 30 26–33 0.117
Weight before pregnancy (kg) 67 58–78 66 59–73 67 60–77 66 60–77 0.750
Body mass index before pregnancy 26.2 22.6–28.1 23.7 21.0–25.5 24.1 21.5–27.9 23.9 22.1–27.1 0.066
Weight at term (kg) 83 72–89 79 71–89 80 74–90 83 74–91 0.399
Weight increase 12 10–18 13 11–16 14 10–17 15 11–19 0.466
Gestational weeks 38.5 38.3–38.7 39.7 39.0–40.6 40.0 39.1–40.9 40.3 39.6–41.0 0.087
Cervical dilatation at admission (cm) 5.0 4.0–7.0 4.0 3.0–4.0 3.0 2.0–4.0 <0.001 <0.001
Duration of labour (hours) 1.6 0.9–3.0 5.9 4.3–8.9 12.2 9.8–14.7 <0.001 <0.001
Duration second stage (hours) 0.2 0.1–0.5 0.5 0.2–1.0 0.6 0.4–1.0 <0.001 <0.001
Oral fluids (ml/hour) 0 0–0 185 79–316 196 136–305 196 154–263 0.429
Intravenous fluid (ml/hour) Not measured Not measured 0 0–0 52 3–102 94 53–144 <0.001 <0.001
Total fluid (ml/hour) Not measured Not measured 194 100–325 291 201–362 314 260–360 <0.001 <0.001
Total fluid (ml) Not measured Not measured 400 200–575 1680 1355–2050 3570 2925–4355
Oxytocin (ml) 0 0–0 50 0–166 200 100–400 <0.001 <0.001
Oxytocin (units) 0.0 0.0–0.0 1.0 0.0–3.3 4.0 2.0–8.0 <0.001 <0.001
Oxytocin (maximum rate mU/minute)* 10 5–20 20 10–30 40 20–60 <0.001 <0.001
Duration epidural (hours) 1.7 1.7–1.7 4.3 2.9–6.1 8.8 6.8–10.6
Osmolality at baseline (mOsm/kg) 279 277–281 280 277–282 280 276–282 279 277–281 0.501
Osmolality postpartum (mOsm/kg) 280 277–282 282 279–284 277 276–281 274 272–277 <0.001 <0.001**
Na at baseline (mmol/l) 137 136–138 137 136–137 136 135–137 136 135–138 0.238
Na postpartum (mmol/l) 137 137–138 136 135–137 135 133–136 133 130–135 <0.001 <0.001**
Na change (mmol/l) 0.0 −1.0 to 1.0 0.0 −1.0 to 1.0 −2.0 −3.0 to −1.0 −3.0 −5.0 to −1.0 <0.001 <0.001**
Glucose at baseline (mmol/l) 5.0 4.5–5.5 5.1 4.7–5.8 5.2 4.9–5.9 5.3 4.8–6.2 0.133
Glucose postpartum (mmol/l) 4.8 4.2–5.1 6.7 5.9–7.9 7.7 6.5–9.4 7.8 6.9–9.4 <0.001 <0.001**
Umbilical cord
Arterial BE −2.0 −3.0 to −1.0 −4.0 −6.0 to −3.0 −5.0 −7.0 to −3.0 −6.0 −9.0 to −3.0 <0.001 0.006**
Arterial pH 7.27 7.24–7.29 7.26 7.22–7.31 7.24 7.19–7.29 7.24 7.17–7.29 0.042 0.014***
Arterial Na (mmol/l) 139 138–140 139 137–140 137 136–139 136 134–138 <0.001 <0.001**
Arterial–venous Na difference (mmol/l) 1.0 0.0–1.0 1.0 0.0–2.0 1.0 0.0–2.0 1.0 0.0–2.0 0.736
Arterial glucose (mmol/l) 3.4 3.0–3.7 4.2 3.6–5.0 5.2 4.2–6.1 5.4 4.7–6.6 <0.001 <0.001**
Infant
Birthweight (g) 3415 3120–3790 3535 3305–3850 3670 3360–4160 3805 3580–4040 0.001 0.001**

All group differences are compared with Kruskal–Wallis nonparametric analysis of variance (ANOVA). When significant differences are found, Mann–Whitney U test is performed to analyse differences between fluid groups 1 and 3.

*

Including only subjects who received oxytocin. Maximum rate mU/minute: maximum rate of oxytocin infusion during first stage of labour.

**

Differences between control group elective caesarean and fluid group 3: P < 0.001 (Mann–Whitney) (additional significant test).

***

Difference between control group elective caesarean and fluid group 3: P = 0.14 (Mann–Whitney) (additional significant test).