TABLE 5.
RT-PCR detection of poliovirus from seeded tap and river water samples
| Filter type | Elutiona | Poliovirus detection in 100-liter seeded samples ofb:
|
|||||
|---|---|---|---|---|---|---|---|
| Tap water
|
River water
|
||||||
| Trial 1 | Trial 2 | Trial 3 | Trial 1 | Trial 2 | Trial 3 | ||
| NanoCeram | First | + | − | + | − | + | + |
| Second | + | + | + | + | + | + | |
| 1MDS | First | − | + | + | − | − | − |
| Second | − | + | + | + | + | − | |
The first elution was done for 1 min, and the second elution was done for 15 min.
+ indicates RT-PCR-positive detection, and − indicates RT-PCR-negative detection.