Skip to main content
Journal of Clinical Microbiology logoLink to Journal of Clinical Microbiology
. 1990 Jun;28(6):1169–1171. doi: 10.1128/jcm.28.6.1169-1171.1990

Evaluation of a human immunodeficiency virus test algorithm utilizing a recombinant protein enzyme immunoassay.

D G Lepine 1, P W Neumann 1, S L Frenette 1, M V O'Shaughnessy 1
PMCID: PMC267898  PMID: 2199490

Abstract

Many truly human immunodeficiency virus (HIV) antibody-negative serum samples may be unnecessarily subjected to costly and time-consuming Western blots (immunoblots). An investigation was undertaken to evaluate the efficiency of using a recombinant protein-based enzyme immunosorbent assay (EIA; Cambridge BioScience [CBC] Recombigen HIV EIA) as an adjunct to whole viral lysate EIA. A total of 2,212 serum samples which had been screened by viral lysate EIA were tested by CBC EIA in parallel with the Western blot. The sensitivity and specificity of the CBC kit were 99.9 and 99.7%, respectively. Positive and negative predictive values were 99.7 and 99.9%, respectively. The high sensitivity of this kit and its high negative predictive value make it an attractive addition to an HIV testing algorithm by reducing the number of Western blot tests on truly antibody negative serum samples.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Burke D. S., Brandt B. L., Redfield R. R., Lee T. H., Thorn R. M., Beltz G. A., Hung C. H. Diagnosis of human immunodeficiency virus infection by immunoassay using a molecularly cloned and expressed virus envelope polypeptide. Comparison to Western blot on 2707 consecutive serum samples. Ann Intern Med. 1987 May;106(5):671–676. doi: 10.7326/0003-4819-106-5-671. [DOI] [PubMed] [Google Scholar]
  2. Burke D. S., Brundage J. F., Redfield R. R., Damato J. J., Schable C. A., Putman P., Visintine R., Kim H. I. Measurement of the false positive rate in a screening program for human immunodeficiency virus infections. N Engl J Med. 1988 Oct 13;319(15):961–964. doi: 10.1056/NEJM198810133191501. [DOI] [PubMed] [Google Scholar]
  3. Carlson J. R., Bryant M. L., Hinrichs S. H., Yamamoto J. K., Levy N. B., Yee J., Higgins J., Levine A. M., Holland P., Gardner M. B. AIDS serology testing in low- and high-risk groups. JAMA. 1985 Jun 21;253(23):3405–3408. [PubMed] [Google Scholar]
  4. Mortimer J. Y. The influence of assay sensitivity and specificity on error rates in three anti-HIV testing strategies. AIDS. 1989 Apr;3(4):199–207. doi: 10.1097/00002030-198904000-00002. [DOI] [PubMed] [Google Scholar]
  5. Ozanne G., Fauvel M. Performance and reliability of five commercial enzyme-linked immunosorbent assay kits in screening for anti-human immunodeficiency virus antibody in high-risk subjects. J Clin Microbiol. 1988 Aug;26(8):1496–1500. doi: 10.1128/jcm.26.8.1496-1500.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Ransohoff D. F., Feinstein A. R. Problems of spectrum and bias in evaluating the efficacy of diagnostic tests. N Engl J Med. 1978 Oct 26;299(17):926–930. doi: 10.1056/NEJM197810262991705. [DOI] [PubMed] [Google Scholar]
  7. Reesink H. W., Lelie P. N., Huisman J. G., Schaasberg W., Gonsalves M., Aaij C., Winkel I. N., van der Does J. A., Hekker A. C., Desmyter J. Evaluation of six enzyme immunoassays for antibody against human immunodeficiency virus. Lancet. 1986 Aug 30;2(8505):483–486. doi: 10.1016/s0140-6736(86)90358-2. [DOI] [PubMed] [Google Scholar]
  8. Resnick L., diMarzo-Veronese F., Schüpbach J., Tourtellotte W. W., Ho D. D., Müller F., Shapshak P., Vogt M., Groopman J. E., Markham P. D. Intra-blood-brain-barrier synthesis of HTLV-III-specific IgG in patients with neurologic symptoms associated with AIDS or AIDS-related complex. N Engl J Med. 1985 Dec 12;313(24):1498–1504. doi: 10.1056/NEJM198512123132402. [DOI] [PubMed] [Google Scholar]
  9. Schüpbach J., Popovic M., Gilden R. V., Gonda M. A., Sarngadharan M. G., Gallo R. C. Serological analysis of a subgroup of human T-lymphotropic retroviruses (HTLV-III) associated with AIDS. Science. 1984 May 4;224(4648):503–505. doi: 10.1126/science.6200937. [DOI] [PubMed] [Google Scholar]
  10. Shaw G. M., Hahn B. H., Arya S. K., Groopman J. E., Gallo R. C., Wong-Staal F. Molecular characterization of human T-cell leukemia (lymphotropic) virus type III in the acquired immune deficiency syndrome. Science. 1984 Dec 7;226(4679):1165–1171. doi: 10.1126/science.6095449. [DOI] [PubMed] [Google Scholar]
  11. Sivak S. L., Wormser G. P. Predictive value of a screening test for antibodies to HTLV-III. Am J Clin Pathol. 1986 Jun;85(6):700–703. doi: 10.1093/ajcp/85.6.700. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES