Skip to main content
. Author manuscript; available in PMC: 2010 Apr 15.
Published in final edited form as: J Neurol Sci. 2009 Apr 15;279(1-2):99–105. doi: 10.1016/j.jns.2008.11.009

Table 1.

Scanner information and parameters

1.5T 3T
Coil: Spinal phased array Spinal phased array
 Gradient strength (max) 23 mT/m 20 mT/m
 Model Number 5351 9900983
 Number of channels 4 8
 Manufacturer Philips General Electric
 Interleaving No Yes
 Cardiac gating No No
 Motion compensation Yes Yes
Sequence T2 fast spin echo T2 fast spin echo
Field of view (cm) 24 × 24 24 × 19
Matrix size 256 × 256 256 × 256
Slice thickness (mm) 3 (no gap) 3 (no gap)
Repetition time (TR) (milliseconds) 9189 6116.66
Echo time (TE) (milliseconds) 100 110.24
Echo train length 40 12
Number of signal averages 2 2
Flip angle (degrees) 90 90
Pixel size (mm) .898 × .898 .937 × .937
Total acquisition time (range) 18.5 – 20 minutes 22.5 – 32 minutes