TABLE 3.

Pulmonary function tests

Original OxyMask
Modified OxyMask
Measured Predicted (%) Measured Predicted (%)
Spirometry
  FVC, L 1.87±0.66 57.38±13.20 1.63±0.53 52.33±14.06
  FEV1, L 1.22±0.56 51.54±21.50 0.99±0.54 44.75±23.56
  FEV1/FVC, % 65.06±19.29 59.7±22.5
  FEF50%, L/s 1.38±1.23 42.15±34.71 1.40±1.82 46.92±64.92
  FEF75%, L/s 0.40±0.32 25.23±18.66 0.35±0.34 23.33±21.63
  Vital capacity, L 2.00±0.80 60.20±15.05 1.66±0.58 53.89±13.33
ABG (room air)
  pH 7.40±0.05 7.40±0.04
  P CO2, mmHg 47.58±6.07 51.08±14.46
  P O2, mmHg 52.75±7.56 51.83±8.44
  SaO2, % 87±6 86±7
  HCO3, mmol/L 30.00±4.07 31.83±7.49

Data are presented as means ± SD. There were no significant differences in spirometry or arterial blood gases (ABG) between patients who used the original and those who used the modified OxyMask (Southmedic Inc, Canada). FEF50% Forced expiratory flow at 50% of vital capacity; FEF75% Forced expiratory flow at 75% of vital capacity; FEV1 Forced expiratory volume in 1 s; FVC Forced vital capacity; HCO3 Bicarbonate concentration; PCO2 Partial pressure of carbon dioxide; PO2 Partial pressure of oxygen; SaO2 Blood oxygen saturation