Reliability of Sagittal Magnetic Resonance Imaging Sequence in Different Articular Surfaces

Articular Surface Variable Value 95% CIs*
Patella Sensitivity 57.1 25.5-84.2
Specificity 50 18.8-81.2
Diagnostic accuracy 53.9 29.1-76.8
Medial Femoral Condyle Sensitivity 77.8 45.3-93.7
Specificity 100 51.0-100
Diagnostic accuracy 84.6 57.8-95.7
Lateral Femoral Condyle Sensitivity 25 7.1-59.1
Specificity 60 23.1-88.2
Diagnostic accuracy 38.5 17.7-64.5
Medial tibial Plateau Sensitivity 58.3 32.0-80.7
Specificity 100 20.7-100
Diagnostic accuracy 61.54 35.5-82.3
Lateral tibial Plateau Sensitivity 18.2 5.1-47.7
Specificity 100 34.2-100
Diagnostic accuracy 30.8 12.7-57.6
*