Table 2.
1 Hz, GSAC = 0 nS |
%Change From GSAC = 0 nS |
|||||||
---|---|---|---|---|---|---|---|---|
1 Hz, GSAC = 2 nS | 3 Hz, GSAC = 0 nS | 3 Hz, GSAC = 2 nS | ||||||
Control solution | ||||||||
RMP, mV | −78.6±0.6 | −2.7±0.4* | −4.3±0.8 | −23.0±4.1* | ||||
APD30, ms | 3.9±0.7 | −4.5±5.1 | 4.0±3.3 | −1.1±1.5 | ||||
APD50, ms | 8.5±2.1 | −3.9±2.5 | 2.7±2.8 | 0.9±1.3 | ||||
APD90, ms | 28.6±2.6 | 6.2±5.6* | 2.2±2.3 | 33.6±14.1* | ||||
APA, mV | 98±25 | −12.6±17 | −0.4±1.2 | −0.6±2.0 | ||||
10-min Exposure to 100 μM H2O2 | ||||||||
RMP, mV | −79.5±0.5 | −4.5±0.6† | −14.7±7.8 | −19.6±5.4† | ||||
APD30, ms | 3.8±0.9 | −1.8±1.4 | −1.5±2.0 | −21±19.8 | ||||
APD50, ms | 8.3±0.3 | −4.9±6.2 | −2.5±1.9 | 6.6±4.8 | ||||
APD90, ms | 33.3±6.2 | 2.3±2.4 | 4.9±4.6 | 24±4.2† | ||||
APA, mV | 103.0±3.8 | −8.7±6.1 | 11.5±12.3 | −1.1±2.5 |
Values are means ± SE; n = 12.
P < 0.05 compared with 1 Hz for control solution with GSAC = 0 nS.
P < 0.05 compared with 1 Hz for 100 μM H2O2 with GSAC = 0 nS.