Skip to main content
. 2009 Apr 10;75(11):3477–3483. doi: 10.1128/AEM.00285-09

TABLE 4.

Sensitivity (CT values) of 529 PCR using the Roche ready-to-use buffer (master hybridization probes) and in-house PCR mix in the detection of T. gondii oocysts seeded into storm water concentratesa

Estimated no. of oocyst/ 0.5 ml water concentrate Master hybridization probe kit (Roche)
In-house mixture
P
Positive rate CT
Positive rate CT
Mean SD Mean SD
1,600 4/4 22.75 4.27 4/4 24.75 0.96 1.000
800 4/4 25.25 4.57 4/4 26.25 0.96 1.000
400 4/4 26.00 4.00 4/4 27.25 0.50 1.000
200 4/4 27.75 2.87 4/4 28.25 0.96 1.000
100 4/4 33.25 9.84 4/4 29.25 0.96 1.000
50 3/4 30.00 0.00 4/4 30.25 0.96 0.500
25 4/4 35.00 10.03 4/4 30.75 0.96 1.000
10 3/4 31.33 1.15 4/4 32.25 1.71 0.500
5 3/4 34.67 2.31 2/4 31.50 0.71 0.500
1 1/4 33.00 2/4 33.00 2.83 0.500
0 0/4 0/4 1.000
a

Dashes indicate no amplification. P values for differences were determined by chi-square analysis.