Table II.

Dose constraints for organs at risk in IMRT plan optimization.

Organs at risk Dose constraint
Spinal cord Maximum dose < 4500 cGy
Esophagus D20% < 1500 cGy
Heart D15% < 3000 cGy
Total Lung D25% < 2000 cGy