. 2009 Apr 1;47(6):1742–1749. doi: 10.1128/JCM.02339-08

TABLE 2.

Specificities and sensitivities of different real-time PCR assays on rhinovirus and enterovirus plasmid-derived constructs

Targeta Results from indicated assaysb
RHP1 RHP2 Panenterhino Panenterhino/Ge/08 HEV Entero/Ge/08
HRV-2 34.7 (±0.2) Neg 34.2 (±0.2) 34.5 (±0.2) Neg Neg
HRV-14 Neg 42.7 (±2.1) 34.3 (±0.5) 35.3 (±1.3) Neg 36.3 (±2.3)
HRV-C Neg Neg 34.9 (±0.1) 34.7 (±0.1) Neg Neg
HRV-C′ Neg Neg 46.5 (±6.5) 37.4 (±0.7) Neg Neg
EV-71 Neg Neg 35.7 (±0.2) 35.6 (±0.4) 33.9 (±0.3) 31.9 (±0.2)
EV-104 Neg Neg 34.7 (±0.2) 34.6 (±0.2) Neg 35.2 (±0.1)
a

HRV- and HEV-derived plasmids were used at a uniform concentration of 1,000 copies of input per PCR. Plasmid constructs are described in Materials and Methods. Results are indicated as real-time PCR CT values (± standard deviations).

b

Neg, negative result.