Table 3.
Results of receiver operating characteristic analysis for detection of Alzheimer’s disease with TYM in 94 patients with Alzheimer’s and 282 age matched controls
Score | False +ve rate | Specificity (%) | False −ve rate | Sensitivity (%) | Prevalence | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1% | 5% | 10% | 20% | 30% | ||||||||||||||
PPV | NPV | PPV | NPV | PPV | NPV | PPV | NPV | PPV | NPV | |||||||||
≤38 | 4 | 96 | 25 | 75 | 16 | 100 | 50 | 99 | 68 | 97 | 82 | 94 | 89 | 90 | ||||
≤39 | 5 | 95 | 19 | 81 | 14 | 100 | 46 | 99 | 64 | 98 | 80 | 95 | 87 | 92 | ||||
≤40 | 8 | 92 | 17 | 83 | 9 | 100 | 35 | 99 | 54 | 98 | 72 | 96 | 82 | 93 | ||||
≤41 | 9 | 91 | 13 | 87 | 9 | 100 | 34 | 99 | 52 | 98 | 71 | 97 | 81 | 94 | ||||
≤42 | 14 | 86 | 7 | 93 | 6 | 100 | 26 | 100 | 42 | 99 | 62 | 98 | 74 | 97 | ||||
≤43 | 17 | 83 | 6 | 94 | 5 | 100 | 23 | 100 | 38 | 99 | 58 | 98 | 70 | 97 | ||||
≤44 | 19 | 81 | 5 | 96 | 5 | 100 | 21 | 100 | 36 | 99 | 56 | 99 | 68 | 98 | ||||
≤45 | 25 | 75 | 3 | 97 | 4 | 100 | 17 | 100 | 30 | 100 | 49 | 99 | 62 | 98 |
PPV=positive predictive value; NPV=negative predictive value.