Skip to main content
. 2009 Jan 28;101(4):2166–2185. doi: 10.1152/jn.91088.2008

TABLE 1.

Probability of tightly correlated firing for different cell-type combinations

Property YA–YC YC–YC YA–YA XA–XA XA–YA XA–YC
A. All cell pairs
Correlation probability
    ≥20% RF overlap 22% (69) 49% (35) 22% (18) 19% (103) 12% (50) 3% (67)
    ≥40% RF overlap 31% (49) 63% (27) 29% (14) 22% (89) 14% (42) 3% (60)
    ≥80% RF overlap 59% (22) 64% (11) 40% (5) 37% (38) 13% (16) 6% (34)
B. Cell pairs with same-sign RFs
Correlation probability
    ≥20% RF overlap, same sign 36% (42) 74% (23) 40% (10) 31% (61) 21% (29) 7% (29)
    ≥40% RF overlap same sign 52% (29) 85% (20) 50% (8) 35% (55) 23% (26) 7% (28)
    ≥80% RF overlap same sign 93% (14) 88% (8) 67% (3) 57% (23) 22% (9) 13% (16)
C. Average RF properties of tightly correlated cells pairs
Receptive-field overlap
    Mean ± SD 89.5 ± 11.1% 74.1 ± 17.1% 76.3 ± 20.6% 84.7 ± 20.3% 79.5 ± 16.8 95.0 ± 7.1%
Receptive-field size ratio
    Mean ± SD 1.7 ± 0.9 1.7 ± 0.8 1.3 ± 0.5 1.3 ± 0.3 1.6 ± 0.3 1.5 ± 0.3
Peak-time difference, ms
    Mean ± SD 2.1 ± 1.6 0.6 ± 0.8 0.4 ± 0.8 1.6 ± 1.9 7.0 ± 3.2 3.1 ± 2.2

The probabilities were calculated for cells with different receptive field (RF) overlap, either including all pairs or selecting only cell pairs with receptive fields of the same sign. The bottom three rows of the table provide average values for receptive-field overlap, receptive-field size ratio, and peak-time difference. The numbers in parentheses represent the sample sizes.