Table 4.

Mean full-thickness cell densities (unweighted for distance between frames) estimated by manual and automatic methods at each examination before and after LASIK

Mean Cell Density, cells/mm3 Mean ± SD
Pre-LASIK 1 month 3 months 6 months 1 year 2 years 3 years 5 years
Number of patients 17 17 17 17 17 15 17 16
Manual 32765 ± 3944 28114 ± 4193 28338 ± 4246 28903 ± 2,326 27492 ± 3568 26038 ± 2881 26195 ± 1739 22920 ± 1728
Automatic 31422 ± 3564 27696 ± 2399 28130 ± 3258 27368 ± 2161 25500 ± 2333 26460 ± 1755 25139 ± 2554 24311 ± 2276
Difference -1343 ± 3047 -418 ± 3898 -208 ± 2997 -1535 ± 2525 -1993 ± 3575 422 ± 2228 -1056 ± 1503 1392 ± 1780
Difference as percent of manual -4.1 -1.5 -0.7 -5.3 -7.2 1.6 -4.0 6.1
P:* 0.06 0.19 0.80 0.02 0.007 0.44 0.02 <0.001
MDD:a 1857 1776 2030 - - 1534 - -
*

Probability, generalized estimating equation models

a

MDD : minimum detectable difference, cells mm-3, based on generalized estimating equation models, α = 0.05, β = 0.20.