Table 4.
Custom-FO (CFO) | Prefabricated orthoses (Prefab) | Shoe only (SO) | Overall significance of model | |
Peak Pressure (kPa) | 289.9 (78.1) | 286.8 (78.6) | 280.9 (63.1) | F = 0.482, P = 0.544 |
Maximum Mean Pressure (kPa) | 139.5 (40.2) | 143.3 (37.9) | 146.0 (34.9) | F = 1.600, P = 0.220 |
Pressure Time Integral (kPa.s) | 66.9 (21.0) | 67.8 (24.9) | 74.4 (21.7) | F = 8.639, P = 0.001†* |
Maximum Force (N) | 390.5 (116.6) | 388.1 (117.6) | 383.6 (109.8) | F = 0.309, P = 0.643 |
Force Time Integral (N.s) | 87.5 (27.5) | 88.3 (34.3) | 97.2 (33.6) | F = 6.073, P = 0.006†* |
Area (cm2) | 29.1 (1.0) | 28.7 (0.9) | 27.9 (1.6) | F = 8.101, P = 0.002* |
Time (% rollover) | 89.4 (8.2) | 89.3 (8.8) | 92.1 (5.6) | F = 4.255, P = 0.024 |
†Adjusted significance of difference between SO and Prefab condition p < 0.05
*Adjusted significance of difference between SO and CFO condition p < 0.05
There were no significant differences between the Prefab and CFO condition