Table 6.
HU-treated, mean data, 32°C | ||
---|---|---|
Bilinear fit L = a1t + b1, t < RCP; L = a2t + b2, t ≥ RCP | a1 (μm/min) | 0.014 |
a2 (μm/min) | 0.020 | |
RCP (min) | 39 | |
LRCP (μm) | 9.0 | |
χ2 | 0.1136 | |
r2 | 0.9904 | |
AIC | −92.07 | |
SBIC | −84.75 | |
Linear fit L = at + b | a (μm/min) | 0.019 |
b (μm) | 8.3 | |
χ2 | 0.1791 | |
r2 | 0.9849 | |
AIC | −71.11 | |
SBIC | −63.79 |