Skip to main content
. Author manuscript; available in PMC: 2010 Feb 1.
Published in final edited form as: Chest. 2008 Nov 18;135(2):269–275. doi: 10.1378/chest.08-0919

Table 2. Alveolar Fluid Clearance, Weight Gain, Hemodynamic, and Gas Exchange Variables During ex Vivo Lung Perfusion*.

Measurements All Lungs (n = 30) Maximal AFC (> 14%/h) [n = 16] Submaximal AFC (≤ 14%/h) [n = 14]
AFC, %/h 17 ± 2 26 ± 2 7 ± 1
Pao2/fraction of inspired oxygen
 Initial 214 ± 19 192 ± 15 239 ± 24
 Final 188 ± 20 170 ± 16 209 ± 25
pH
 Initial 7.51 ± 0.03 7.55 ± 0.05 7.47 ± 0.04
 Final 7.47 ± 0.04 7.52 ± 0.05 7.42 ± 0.05
Perfusion flow rate, L/min 0.27 ± 0.01 0.27 ± 0.01 0.26 ± 0.03
Total pulmonary vascular resistance, mm Hg/L/min/100 g
 Initial 15.6 ± 3.3 19.4 ± 5.6 11.4 ± 2.8
 Final 14.8 ± 3.3 18.4 ± 5.6 10.6 ± 2.8
*

Data are presented as mean ± SE.

Beginning of experiment vs end of experiment, p < 0.05.