Skip to main content
. Author manuscript; available in PMC: 2010 Sep 1.
Published in final edited form as: Dent Mater. 2009 Apr 18;25(9):1116–1121. doi: 10.1016/j.dental.2009.03.008

Table 1.

Microtensile peak stress (MPa) with standard deviation of the different test groups. Numbers of specific failure types are represented in percents.

Group Peak Stress (SD)
(MPa)
Adhesive
(%)
Mixed
(%)
Cohesive
(%)
Composite (bars only)a 29.2 (3.7) control
Porcelainb – (control) 25.3 (5.3) 16 35 49
Zirconia (SixOy - 2.6nm thickness)b 23.2 (5.4) 15 40 45
Zirconia (Co-Jet™ treatment)c 18.6 (5.9) 32 52 16
Zirconia (SixOy - 23nm thickness)c 16.2 (5.9) 50 43 7
Zirconia (no treatment)d 7.6 (3.0) 72 28 -