Skip to main content
. 2009 Jun 27;37(9):1739–1756. doi: 10.1007/s10439-009-9747-5

Table 5.

Root mean square (rms) differences in the activation times (δ) and repolarization times (ρ) estimated by using two different TMP shape descriptions

Subject Timing differences for two source models
Depolarization (ms) Repolarization (ms)
NH 1.6 6.4
WPW
    Fusion 2.1 3.6
    AV blocked 6.8 32.5
BG
    Baseline 3.8 9.7
    Peak infusion 3.8 23.1

The two source models used were: (1) with spike and decreasing plateau (Eq. 13) and (2) with constant plateau (Eq. 5)