Skip to main content
. 2009 Jun 24;47(8):2564–2570. doi: 10.1128/JCM.00285-09

TABLE 2.

HPV detection by SPF10-Line Blot 25 for corresponding genital self-obtained smears with liquid-based medium versus FTA cartridge (sample set 2)a

Sample no. HPV detection using self-samples (LBC)
HPV detection using self-samples (FTA cartridge)
HPV accordance
DNA extraction HR LR DNA extraction DNA elution HR LR HR LR
1 18, 51, 54, 68 + + 18, 51, 54, 68 18, 51, 54, 68 + + c c
2 56 + 56 56 + c c
3 X + X X + c c
4 X + X X + c c
5 42, 51, 54 + + 42, 51, 54 42, 51, 54 + + c c
6 52 + 52 52 + c c
7 X + X X + c c
8 16 + 16 16 + c c
9 16, 45, 51 + 11, 16, 45, 51 11, 16, 45, 51 + + c d
10 68 + 68 68 + c c
11 31 + 31 31 + c c
12 39, 54 + + 39 39 + c d
13 54 + X X + c c
14-51 N N N c c
a

HR-HPV types (HR) were 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 59, and 68/73; probable HR-HPV types were 53 and 66. LR-HPV types (LR) were 6, 11, 34, 40, 42, 43, 44, 54, 55, 58, 70, 74, and X. c, concordant; d, discordant; N, HPV negative; −, negative; +, positive.