Skip to main content
. Author manuscript; available in PMC: 2010 Apr 1.
Published in final edited form as: IEEE Trans Biomed Eng. 2009 Jan 23;56(4):1134–1142. doi: 10.1109/TBME.2009.2012721

Fig. 5.

Fig. 5

Comparison of reconstruction results for a radially encoded Shepp-Logan phantom using Kaiser-Bessel gridding method and NUFFT method. Both methods use μ = 2 and q = 4 are used. (a) Difference image between DFT reconstruction and conventional KB reconstruction. IIkb. (b) Difference image between DFT reconstruction and cosine LS-NUFFT reconstruction. IInucos. (c) Difference image between DFT reconstruction and KB LS-NUFFT reconstruction. IInukb.