TABLE II.

Auditory thresholds (in dB HL) and measured crossover frequencies (in Hz) for participants with sloping hearing loss. In addition, bolded thresholds mark potential dead regions as identified by a positive finding with the TEN test using the less conservative criteria described by Moore et al., 2000 (masked threshold at least 10 dB above quiet threshold and at least 10 dB above the level of the masking noise)

Frequency (in Hertz)
Subject Ear Crossover frequency 250 500 1000 1500 2000 3000 4000 6000 8000
DD L 1223 15 25 25 45 60 60 65 60 60
ET R 1451 30 25 35 60 70 65 65 70 65
JS L 1033 20 15 25 30 60 70 75 85 90+
JT L 1377 25 30 45 50 55 65 60 60 65
RC R 1364 30 35 45 55 60 70 70 75 80
MC L 1128 15 20 30 30 55 70 60 55 70
AC R 1198 35 40 55 60 70 70 75 90 95
LC L 1301 30 20 40 60 65 70 70 70 75
BW L 866 20 20 40 45 50 65 80 90 90
MH L 1131 15 25 55 65 65 75 80 90 90